Capacitance and inductance tester operation

time:2021/6/29   source:华天电力  reading:693 time

Operation method of capacitance and inductance tester:


If you need capacitance test, click the "parameter setting" icon button under the main menu screen to enter the capacitance measurement parameter setting interface. In the parameter setting interface, directly click the input box or icon button to set the parameter, and click the "save" icon button to save the current parameter , Click the "Test" icon button to enter the following test interface. After a few seconds of testing, the test result is displayed and the screen is automatically locked, waiting for the user to save or print. Just click the corresponding icon button for each operation. If you want to print the data, please click the "print" icon button; to store the data, click the "save" icon button, if you need to measure, please click the "retest" icon button; click the "exit" icon button to return to the main interface.


Automatic Capacitance Inductance Tester.png


The entire interface can be divided into two parts, the upper "black body" title is the electrical parameter part of the sample, the upper "blue body" title is the capacitance parameter of each phase of the sample calculated according to the electrical parameters of the sample, from left to right are respectively Capacitance parameters of phase a, phase b, and phase c. Single-phase capacitance measurement: Click the "main interface" button in the "single-phase capacitance test" icon to directly measure single-phase capacitance. The display interface is as follows: After a few seconds of testing and the test data is stable, click the lock screen button to lock Screen or continue to measure and wait for the instrument to automatically lock the screen. The operation can be directly clicked on the corresponding icon button. To print the data, click the print button; to store the data, click the save button; to measure the data, click the retest button; to return to the main screen, click the exit button.


The "factory settings" function icon button in the interface, the parameter is set to factory calibration, it is recommended that customers do not change its setting data, otherwise it will cause impermissible test data. If you need to change, you must make it under the guidance of our technicians, and record the set value before the next change in the sequence, so as to be able to restore the failed initial set value.


The use of the capacitance and inductance tester is relatively simple. In the work of electric power workers, as long as they read the product manuals in advance and use them in strict accordance with the rules of use, the equipment can be used well.