Detection Technology
Choose a Relay Tester for Overcurrent Protection
With the acceleration of the construction of new power systems, overcurrent protection, as one of the most basic and widely used protection types in power systems, covers various voltage levels from 10kV distribution networks to ultra-high voltage transmission. However, facing the wide variety of relay protection testers on the market, how to choose a device that truly meets the requirements of overcurrent protection testing has become a practical issue for many power maintenance units and operation teams. Wuhan UHV Power Technology Co., Ltd. has accumulated rich experience in product research and on-site service in the field of relay protection testing. Its technical team has developed a complete set of selection ideas for overcurrent protection testers based on years of practice.
'On demand selection' is the core principle
The core logic of selection lies in "on-demand selection", mainly determining equipment specifications based on testing objects, testing projects, and future expansion needs. For overcurrent protection testing, it is important to focus on the following dimensions.
Channel configuration is the primary consideration factor. Overcurrent protection usually involves synchronous output of three-phase current, therefore at least 3 phase current channels are required. But in testing scenarios involving zero sequence overcurrent protection, a fourth current channel is required for zero sequence current injection. For situations where complex schemes such as differential protection and busbar protection need to be tested, 6-phase current configuration has become the industry standard. The Wuhan UHV-1200 microcomputer relay protection tester can output 6-phase voltage and 6-phase current, supporting various flexible combination modes such as 4-phase voltage, 3-phase current, 6-phase voltage, 6-phase current, and 12 phase output, covering multi-level requirements conventional overcurrent verification to complex differential testing.
The output capacity directly determines the applicability range of the tester. Conventional overcurrent relay testing generally requires a current output capability of 30A to 50A per phase. But when the test object involves large transformers or busbar protection that require high current injection, a model with stronger output capability, such as 75A or higher specifications, should be selected. Taking Wuhan UHV-802 ultra-high voltage as an example, its phase current output range is 0-40A, the three parallel current output can reach 120A, the phase current output power is 450VA, and the three parallel output power can reach 900VA, which can meet the power requirements of most on-site overcurrent verification. The output power indicator is often overlooked, but sufficient power reserve is necessary to ensure that the output signal does not fold under load conditions, thereby ensuring the accuracy of the test results.
Output accuracy is the core indicator of the tester. According to the requirements of DL/T 624 standard, equipment used for detecting relay protection at voltage levels of 110kV and above shall have an accuracy of not less than 0.2 level. The Wuhan UHV-702 microcomputer relay protector adopts a dual chip architecture of DSP+FPGA, with a current output accuracy of 0.2 level, phase error controlled within 0.3 °, and time measurement accuracy of 0.1ms. It can accurately reproduce the action characteristics and time curve of overcurrent protection. For testing projects that are sensitive to phase relationships, such as directional overcurrent protection, the impact of phase accuracy is particularly significant. UHV-1200 further achieves a voltage and current output accuracy of 0.2 level. When outputting 6-phase current, each phase can reach 0-30A, when outputting 3-phase current, each phase can reach 60A, and when 6-phase is connected in parallel, the current output can reach 180A. It is suitable for complex scenarios such as transformer differential testing, plant power fast switching, and backup automatic switching testing.
Software functionality and portability cannot be ignored. The richness of preset testing modules directly affects the efficiency of on-site work. UHV-1200 is equipped with an intelligent testing management system, which has over 200 preset test templates. It can quickly match the best solution according to different testing needs and simulate various complex fault scenarios. In terms of environmental adaptability, Wuhan UHV relay protection tester has performed well. UHV-702 can operate stably in the environment of -20 ℃ to 50 ℃. UHV-1200 has passed the wide temperature certification of -40 ℃ to+70 ℃. It has worked continuously for 12 hours in Xizang Ali PV energy storage project without data drift.
Technical Practice: Photovoltaic Power Plants to Overseas Projects
In the practical application of overcurrent protection testing, the value of professional equipment has been fully verified in various engineering sites. The technical team of Wuhan UHV has provided relay protection testing services for the Hubei Honghu Fishery Photovoltaic Complementary Power Generation Project, covering first and second stage overcurrent protection, direction protection, overload alarm and other projects. In this project, the overcurrent protection has a fixed value of 10A for the first stage and 8A for the second stage. The technicians used a relay protection tester to complete all tests and quickly and accurately searched for boundary points through the power direction module provided by the equipment, efficiently completing the calibration of directional components.
In overseas markets, Wuhan UHV has also demonstrated its technological strength. Recently, the company successfully delivered high-voltage testing equipment to the Gobustan 100MW photovoltaic project in Azerbaijan. The core equipment delivered this time is the UHV-1200 microcomputer relay protection tester 6U+6I and UHV series series series resonant device, which is accurately adapted to the commissioning and operation scenarios of photovoltaic power plants. Among them, UHV-1200 can comprehensively verify the action logic and setting accuracy of the protection device, ensuring the reliable operation of the system under fault conditions; The series resonant device can efficiently complete the equipment withstand voltage test, accurately identify insulation hazards, and build an electrical safety detection system covering the entire process of power station commissioning, operation, and maintenance.
Standard guidance, selection based on evidence
The selection and use of relay protection testers must comply with a series of industry standards. GB/T 7261-2016 "Basic Test Methods for Relay Protection and Safety Automatic Devices" is the most core standard in China, which specifies in detail the test conditions and methods for various types of protection devices. DL/T 624-2023 "Technical Conditions for Microcomputer based Test Devices for Relay Protection" specifies the technical parameters, functions, and safety requirements of microcomputer based testers, and adds IEC 61850 digital interface capabilities to support SV/GOOSE verification at the process layer of intelligent substations. At the international level, IEC 60255-151 provides clear requirements for the functional requirements, measurement characteristics, and delay characteristics of overcurrent/undercurrent protection, which is the internationally recognized basis for overcurrent protection testing. When purchasing testing equipment, users should confirm whether the equipment meets the above standard requirements and regularly send the equipment to qualified metrology institutions for calibration, usually with a calibration cycle of one year.
The perspective of industry development trends, relay protection testers are evolving towards higher accuracy, stronger protocol compatibility, and better portability. For the purchaser, in addition to paying attention to the technical parameters of the equipment during selection, they should also comprehensively evaluate the supplier's after-sales service system, technical training capabilities, and software upgrade support to ensure that the equipment maintains stable testing performance in long-term use. Wuhan UHV has stated that it will continue to focus on technological innovation and product optimization in the field of power testing, providing reliable electrical testing solutions and technical support for more substations and new energy stations.
Choose a Relay Tester for Distance Protection | 2026/9/29 | reading396time How to Choose a Primary Current Injection Test Set | 2026/9/24 | reading403time return