Detection Technology
Related knowledge of series resonance
1、 Definition
In a series circuit composed of resistors, inductors, and capacitors, when the capacitive reactance XC is equal to the inductive reactance XL, i.e. XC=XL, the phase of the voltage U and current I in the circuit are the same, and the circuit exhibits pure resistive behavior. This phenomenon is called series resonance. When a series resonance occurs in the circuit, the impedance of the circuit Z=√ R2+XC-XL2=R, the total impedance in the circuit is minimized, and the current will reach its maximum value.
2、 Harmfulness
When resonance occurs, due to the equal inductance and capacitance, the effective values of the voltage across the inductance and capacitance are equal, that is, UL=UC. Due to their opposite phases, these two voltages cancel each other out. The effective voltage value of a capacitor or inductor is: UL=UC=XLI0=ω 0LIO=ω 0LU/R. In the formula, ω 0L/R is referred to as the quality factor of the resonant circuit, which represents the voltage ratio. Namely UC/U or UL/U.
Quality factor is an important parameter for measuring the characteristics of resonant circuits. The larger the reactance and the smaller the resistance in a circuit, the higher the quality factor. Therefore, the voltage value on the capacitor or inductor will be much higher than the applied voltage. The quality factor of general inductor and capacitor resonant circuits can reach tens or even hundreds. So series resonance is also called voltage resonance. In the power system, series resonance will generate overvoltage several times higher than the rated voltage of the grid, which poses a great threat to the safety of power equipment.
In the R-L-C series circuit, the phenomenon where the voltage and current at the line end are in phase is called series resonance.
Wuhan UHV Power produces XZB-H series resonant boost device (for CVT verification), XZB-G AC voltage withstand resonant device, and BPXZ-H frequency conversion resonant voltage withstand test device, which are widely used for AC voltage withstand testing of various high-voltage cross-linked cables, transformers, generators, GIS switches, motors and other equipment. The device has multiple key national patented technologies, combined with some imported international advanced technologies, and the overall equipment has reached the international advanced level. Fully foolproof operation, fully automated testing.
Misconceptions in the operation of a megohmmeter | 2025/5/16 | reading392time Measure insulation resistance using a megohmmeter | 2025/5/15 | reading402time return