HuaTianLogo

Power detection technology / Power detection

Detection Technology

Safety measures before high voltage test

time:2020/10/9   source:华天电力  reading:956 time

Insulation defects of high-voltage test transformers are an important factor leading to equipment failures. In the current power system accidents, a large part of them are caused by insulation defects, so in order to effectively reduce the probability of accidents. During power operation, electric power professionals can use various high-voltage test methods to effectively test the data and information of the equipment during operation, so as to judge the feasibility of equipment operation.


Hipot Test Set.png


There are many types of high-voltage test transformers. Under normal circumstances, the high-voltage test of power transformers can be divided into two categories, characteristic test and insulation test. The characteristic test is mainly for the main circuit contact resistance of the circuit breaker of electrical equipment such as power transformers. , Ampere curve and polarity test. The insulation test includes two types: destructive and non-destructive. The former involves withstand voltage tests such as DC and AC. Because of its higher voltage, it is easy to find defects in the equipment during the test. But because it is destructive, it is easy to damage the insulation of the equipment during the test, which greatly reduces the length of its life. The latter is generally tested with non-destructive methods, and defects in the overall electrical equipment can be found. But because of the relatively low voltage, the sensitivity is relatively low. The effects produced by different experiments are also different. However, in actual tests, non-destructive tests are still a more common test method.


High-voltage test transformers are easily damp, usually caused by their outer skin. Normally, the electrical properties of water molecules in the electric field are positive. But if a positive voltage is applied to the windings of the transformer, it will cause changes in water molecules. The amount of water continues to decrease, so the amount of current passing through the transformer will also decrease. When the applied voltage is negative, the amount of current passing through the transformer will increase. But in reality, not all transformers are affected by voltage polarity. For example, new power transformers generally do not suffer from moisture. Therefore, the water content in the new transformers is extremely low, or even negligible. It seems that there is no certainty between the polarity of the test voltage and the current leakage. .


In order to ensure safe and accurate work, power transformers are an important guarantee for the safe operation of power high-voltage test transformers. The high-voltage test requires high professionalism, so professional and technical personnel with strong professional knowledge should be selected for the test. At the same time, various safety protection measures should be done before the test, and the test skills should be flexibly mastered during the test. So as to avoid the occurrence of various factors that affect the test results, so as to ensure the accuracy of the test results.


Copyright description: all articles, pictures, video and other materials on this site belong to wuhan huatian power automation co., LTD. For use, please contact us; Permission to reprint articles, pictures, video and other materials please quote "from: huatian power".

Existing test method of loop resistance tester  | 2020/10/9 | reading920time How to use the circuit breaker tester  | 2020/10/8 | reading906time return