Necessary test equipment for power equipment inspection and preventive test
stake: About product purchase、Technical maintenance and other services,Send welcome email:
Inflatable test transformer is a necessary test equipment for power equipment test and preventive test.With the development of China's power industry,The requirement of voltage grade of test transformer is higher and higher,And the traditional oil-immersed test transformer,No matter in the volume and weight or in the performance are increasingly unable to meet the requirements of field work.
With the progress of basic science research in China,advanced material,Application of new process,The new medium sulfur hexafluoride gas is introduced into the application field of power equipment.Because of the excellent insulation and arc extinguishing performance of sulfur hexafluoride gas,And incombustibility,It is widely used as a new insulating medium.
Our company has been working hard for many years,Inflatable ac test transformer is studied successfully,This series of inflatable test transformer is compared with traditional oil-immersed lightweight test transformer,You lose weight20%-60%(It depends on voltage and capacity level),And no oil pollution,The voltage grade of single inflatable test transformer can be reached300kV.Due to the inflatable test transformer with a new production process,The technical performance of the product has been greatly improved,Especially suitable for field work and frequently moving working conditions.
Product nickname:YDQAc-dc SF6 gas test transformer、YDQ、HT testing transformer、Power voltage test transformer、Ultra-light high-voltage test transformer、Cascade high voltage test transformer、Inflatable test changes、variable volume、Aeration test change、Inflatable light pressure test changes
voltage classes | 10kV~300kV |
range of capacity | 1~500kVA |
no-load current | <7% |
impedance voltage | <8% |
product classification | interflow、ac/dc、Ac cascade、Ac-dc cascade |
specifications and models | capacity(kVA) | High Voltage(kV) | High tension current(mA) | low input voltage converter | bend-beam-rheometer | temperature rise℃(30 minutes) | |
voltage(V) | electricity(A) | ||||||
YDQ-1.5/50 | 1.5 | 50 | 30 | 200 | 7.5 | 500 | 10 |
YDQ-3/50 | 3 | 50 | 60 | 200 | 15 | 500 | 10 |
YDQ-5/50 | 5 | 50 | 100 | 200 | 25 | 500 | 10 |
YDQ-10/50 | 10 | 50 | 200 | 200 | 50 | 500 | 10 |
YDQ-20/50 | 20 | 50 | 400 | 400 | 53 | 500 | 10 |
YDQ-30/50 | 30 | 50 | 600 | 400 | 79 | 500 | 10 |
YDQ-50/50 | 50 | 50 | 1000 | 400 | 12 | 500 | 10 |
YDQ-5/100 | 5 | 100 | 50 | 200 | 25 | 1000 | 10 |
YDQ-10/100 | 10 | 100 | 100 | 200 | 50 | 1000 | 10 |
YDQ-20/100 | 20 | 100 | 200 | 400 | 53 | 1000 | 10 |
YDQ-30/100 | 30 | 100 | 300 | 400 | 79 | 1000 | 10 |
YDQ-50/100 | 50 | 100 | 500 | 400 | 132 | 1000 | 10 |
YDQ-20/150 | 20 | 150 | 133 | 400 | 53 | 1500 | 10 |
YDQ-30/150 | 30 | 150 | 200 | 400 | 80 | 1500 | 10 |
YDQ-50/150 | 50 | 150 | 333 | 400 | 132 | 1500 | 10 |
YDQ-100/150 | 100 | 150 | 667 | 400 | 263 | 1500 | 10 |
YDQ-50/200 | 50 | 200 | 250 | 400 | 132 | 2000 | 10 |
YDQ-100/200 | 100 | 200 | 500 | 400 | 263 | 2000 | 10 |
YDQ-150/200 | 150 | 200 | 750 | 400 | 395 | 2000 | 10 |
YDQ-200/200 | 200 | 200 | 1000 | 400 | 526 | 2000 | 10 |
YDQ-300/200 | 300 | 200 | 1500 | 400 | 790 | 2000 | 10 |
YDQ-50/300 | 50 | 300 | 170 | 400 | 132 | 3000 | 10 |
YDQ-100/300 | 100 | 300 | 333 | 400 | 263 | 3000 | 10 |
YDQ-150/300 | 150 | 300 | 500 | 400 | 395 | 3000 | 10 |
YDQ-200/300 | 200 | 300 | 667 | 400 | 526 | 3000 | 10 |
YDQ-300/300 | 300 | 300 | 1000 | 400 | 790 | 3000 | 10 |
1.The appearance of the product shall be subject to the actual product,If there are any changes in technical parameters and models,without prior notice.If there is theft or copying,Legal responsibility will be pursued.
2.For more information aboutWuhan UHV, please enter product center . Service email:info@hvtest.cc
1、The inflatable test transformer is small in size,in light weight(It is 40%-65 lighter than the same grade oil-immersed transformer)
2、spotless,greaseless,There is no need to maintain
3、Free from adverse weather and environment,The field transport should be stationary and can be tested
4、The insulation strength is obviously higher than that of oil-immersed transformer,Minimal corona
Enterprise products in strict accordance with international and national standards and rules of industry production, through the national, provincial and municipal electric power research institute and electric power authorities detection, measuring center, fully passed the ISO9001 international quality management system certification, the licence for manufacturing measuring instruments of the People's Republic of China, GB/T19001-2016 quality management system requirements, GB/T24001-2016 environmental management system requirements, GB/T45001-2020 occupational health and safety management system requirements.
email: info@hvtest.cc
Skype: Tina Qiao
+8615172408058