HuaTianLogo
Circuit Breaker Analyzer (Double Grounded)

UHV-406 Circuit Breaker Analyzer (Double Grounded)

It can accurately measure the mechanical dynamic characteristics of high-voltage circuit breakers of various voltage levels, such as less oil, more oil, vacuum and sulfur hexafluoride

Reference standard: GB 1984-2014, DL/T 846.3-2017

Note: Regarding product purchase, technical maintenance and other services, welcome to send email:

Product Introduction

With the development of society, people have higher and higher requirements for the safety and reliability of electricity. The high-voltage circuit breaker is responsible for the dual tasks of control and protection in the power system, and its performance is directly related to the safe operation of the power system. Mechanical characteristic parameter is one of the important parameters to judge circuit breaker performance. The instrument provides convenience for dynamic analysis of various types of circuit breakers, and can accurately measure the mechanical dynamic characteristics of various voltage levels of high-voltage circuit breakers such as less oil, more oil, vacuum and sulfur hexafluoride. The high voltage circuit breaker is responsible for the dual tasks of control and protection in the power system, and its performance is directly related to the safe operation of the power system. Mechanical characteristic parameter is one of the important parameters to judge circuit breaker performance.

Product nickname:High voltage switch mechanical characteristic tester, switch mechanical characteristic tester, high voltage switch comprehensive tester, circuit breaker dynamic characteristic tester, circuit breaker mechanical characteristic tester, circuit breaker comprehensive tester, high voltage switch time characteristic tester, high voltage switch characteristic tester, switch characteristic tester, circuit breaker tester, switch mechanical characteristic tester, switch parameter tester, high voltage open Switching characteristic tester

Product Parameters

Technical Parameters

Time measurement 12 natural switching (closing) time
The opening (closing) phase is not at the same time
The difference between different periods of switching (closing)
Closing (opening) Bouncing time (number of bounces)
Different testing range: 1ms ~ 99ms, resolution: 0.01ms
Internal trigger test range: 1ms ~ 999ms, resolution: 0.01ms
1000ms ~ 9999ms, resolution: 0.1ms,10000ms to 200000ms Resolution: 1ms
External trigger test range: 0.01ms ~ 200s
Accuracy within 1000ms: 0.05%±0.1ms
velocity measurement instant separating (instant closing) velocity
Appointed time slot (stroke segment or angle segment) average
velocity
velocity measurement Just minute (just combined) speed
Average speed for a specified period of time (stroke or Angle)
Measuring range 0.1mm sensor 0.01 ~ 20.00m/s
345° Angle sensor 0.01 ~ 20.00m/s
Laser sensor 0.01 ~ 15.00m/s
Travel measurement 3. Moving contact stroke (stroke) (optional for 3-way stroke measurement)
Contact stroke (open distance)
Over travel
Overshoot or rebound stroke
Measuring range Linear sensor: 50mm, measuring range: 0-50mm, resolution :0.1mm
Rotating sensor: 345°, measuring range: 0-1000mm, resolution: 0.08°
The sensor has an invalid area of 15 degrees, and the effective area of the sensor can be seen in the instrument during installation, and the value displayed is about 160-200 degrees.
Acceleration sensor measurement range: 0-300mm, resolution: 0.1mm
Coil current Maximum current 20A, resolution: 0.01A
Coil resistance measurement range 0 ~ 2000Ω, resolution: 0.01Ω
Instrument power supply AC220V ± 10%; 50Hz ± 10%
Dc power output DC6 ~ 270V continuous adjustable, DC24V≤15A (short time), DC220V≤ 20A(short time)
External trigger voltage 10.AC/DC10-300V, current ≤120A
Isolation switch measurement range (1) Voltage output: DC6~270V(adjustable)
(2) Power output time: 0.01-20 seconds (configurable)
(3) The maximum acquisition time of the fracture signal is 200 seconds
(4) Can measure fracture closing, opening time, three-phase different periods, bounce time and number
Mainframe volume 400×263×175mm
Use environment -20℃~+50℃
Relative humidity ≤90%
Note:

1. The appearance of the product is subject to the actual product. The Technical Parameters and model numbers are subject to change without notice. If there is misappropriation or copying, legal liability will be pursued.

2. For more information about Wuhan UHV, please enter product center . Service email:info@hvtest.cc

Product features

Circuit Breaker Analyzer (Double Grounded) Circuit Breaker Analyzer (Double Grounded) Circuit Breaker Analyzer (Double Grounded) Circuit Breaker Analyzer (Double Grounded) Circuit Breaker Analyzer (Double Grounded) Circuit Breaker Analyzer (Double Grounded) Circuit Breaker Analyzer (Double Grounded)
-->

Product Picture

Product attachment diagram

Product details

Product Certificate

Enterprise products in strict accordance with international and national standards and rules of industry production, through the national, provincial and municipal electric power research institute and electric power authorities detection, measuring center, fully passed the ISO9001 international quality management system certification, the licence for manufacturing measuring instruments of the People's Republic of China, GB/T19001-2016 quality management system requirements, GB/T24001-2016 environmental management system requirements, GB/T45001-2020 occupational health and safety management system requirements.