Meet the test range

1, 10kV/300mm2 cable 1.5km AC voltage test, capacitance ≤0.5632μF, test frequency 30-300Hz, test voltage 22kV, test time 5min.

2, 35kV/300mm2 cable 0.35km AC withstand voltage test, capacitance ≤0.0681μF, test frequency 30-300Hz, test voltage 52kV, test time 60min.

3, 35kV main transformer AC withstand voltage test, capacitance ≤0.02μF, test frequency 45-65Hz, test voltage does not exceed 68kV, test time 1min.

4, 10kV switch and other electrical equipment AC withstand voltage test, test frequency 30-300Hz, test voltage does not exceed 42kV, test time 1min.

Main components of the device

Serial number Device name Specification and model Unit Quantity
1 Variable frequency power supply UHV-4kW Tower 1
2 Excitation transformer UHV-4kVA/1.5/3/6kV/0.4kV Tower 1
3 High voltage reactor UHV-25kVA/25kV Section 3
4 Capacitive voltage divider UHV-1000pF/80kV Set 1

Main technical parameters and functions

Rated capacity 75kVA
Rated voltage 25k;75kV
Rated current 3A;1A
Measurement accuracy System RMS level 1.5
Operating frequency 30-300Hz
Device output waveform Sinusoidal wave
Quality factor Device Q≥30(f=45Hz)
Waveform distortion rate Output voltage waveform distortion ≤1%
Input power supply Single-phase 220 or three-phase 380V voltage, frequency 50Hz
Working hours Allow continuous 60min under rated load; Overpressure 1.1 times 1 minute
Temperature rise Temperature rise ≤65K after continuous operation under rated load for 60 minutes
Protection function Overvoltage, overcurrent, zero start, system mismatch (flashover) and other protection functions
Ambient temperature -20℃-55℃
Relative humidity ≤90%RH
Altitude ≤3000m

Device capacity verification (device capacity is 75kVA, divided into three reactors, reactor single section is 25kVA/25kV/1A/110H)

Serial number Test Test Frequency Test Current
1 AC withstand voltage test for 10kV/300mm² cable 1.5km, capacitance ≤0.5632μF, test frequency 30-300Hz, test voltage 22kV, test time 5min, using three reactors in parallel, then L=110/3=36.7H f=1/2π√(LC)=1/(2×3.14×√(36.7×0.5632×10⁻⁶))=35.01Hz I=2πfCU=2π×35.01×0.5632×10⁻⁶×22×10³=2.73A
2 AC withstand voltage test for 35kV/300mm² cable 0.35km, capacitance ≤0.0681μF, test frequency 30-300Hz, test voltage 52kV, test time 60min, using three reactors in series (mutual inductance coefficient 1.2), L=110×3×1.2=396H f=1/2π√(LC)=1/(2×3.14×√(396×0.0681×10⁻⁶))=30.65Hz I=2πfCU=2π×30.65×0.0681×10⁻⁶×52×10³=0.68A
3 AC withstand voltage test for 35kV main control, capacitance ≤0.02μF, test frequency 45-65Hz, test voltage not exceeding 68kV, test time 1min, using three reactors in series (mutual inductance coefficient 1.2), then L=110×3×1.2=396H f=1/2π√(LC)=1/(2×3.14×√(396×0.02×10⁻⁶))=55.55Hz I=2πfCU=2π×55.55×0.02×10⁻⁶×68×10³=0.48A

Equipment combination method during testing

Test Object Combination Method
Reactor Selection
(25kVA/25kV Three Sections)
Excitation Transformer
Output Selection
Test Voltage
(kV)
10kV/300mm 2 Cable 1.5km Use three reactors in parallel 1.5kV ≤22kV
35kV/300mm 2 Cable 0.35km Use three reactors in series 3kV ≤52kV
35kV Transformer Multiple Current Withstand Test Use three reactors in series 6kV ≤68kV
10kV Switch and Other Electrical Equipment Use three reactors in series 3kV ≤42kV

System Configuration Parameters

(一) Variable Frequency Power Supply UHV-4kW (1 unit)
Rated Output Capacity 4kW
Power Supply 220/380±10%V (Single/Three Phase), Power Frequency
Output Voltage 0-400V
Rated Input Current 10A
Rated Output Current 10A
Voltage Resolution 0.01kV
Voltage Measurement Accuracy 1.5%
Frequency Adjustment Range 30-300Hz
Frequency Adjustment Resolution ≤0.1Hz
Frequency Stability 0.1%
Operating Time Continuous 60min at Rated Capacity
Maximum Component Temperature at Continuous 60min Operation at Rated Capacity ≤65K
Noise Level ≤50dB
Dimensions (L×W×H mm) 400×280×400
Weight Approximately 10kg
(二) Excitation Transformer UHV-4kVA/1.5/3/6kV/0.4kV (1 unit)
Rated Capacity 4kVA
Input Voltage 0-400V
Output Voltage 1.5/3/6kV
Structure Dry Type
Dimensions (L×W×H mm) 450×330×430
Weight Approximately 45kg
(三) High Voltage Reactor UHV-25kVA/25kV (3 units)
Rated Capacity 25kVA
Rated Voltage 25kV
Rated Current 1A
Inductance 110H/unit
Quality Factor Q≥30(f=45Hz)
Structure Dry Type
Dimensions (Inner Diameter×Height mm) 282×435
Weight Approximately 45kg
(四) Capacitive Voltage Divider UHV-1000pF/80kV (1 set)
Rated Voltage 80kV
High Voltage Capacitance 1000pF
Dielectric Loss tgσ≤0.5%
Voltage Division Ratio 1000:1
Measurement Accuracy Effective Value 1.5 Grade
Dimensions (Inner Diameter×Height mm) 140×1000
Weight Approximately 8kg

Delivery List

No. Equipment Name Model and Specifications Unit Quantity
1 Variable Frequency Power Supply UHV-4kW Unit 1
2 Excitation Transformer UHV-4kVA/1.5/3/6kV/0.4kV Unit 1
3 High Voltage Reactor UHV-25kVA/25kV Section 3
4 Capacitive Voltage Divider UHV-1000pF/80kV Set 1
5 Internal Connection Cables
Set 1
6 Factory Inspection Report
Copy 1
7 User Manual
Copy 1
8 Product Certificate
Copy 1
9 Packing List
Copy 1

Reference Test Standards

DL/T 596-1996 "Preventive Test Code for Electric Power Equipment"
GB50150-2016 "Standard for Handover Testing of Electrical Equipment in Electrical Installation Engineering"
GB10229-88 "Reactors"
GB1094 "Power Transformers"
GB1094.1-GB1094.6-96 "Degrees of Protection Provided by Enclosures"
GB2900 "Electrotechnical Terminology"
GB/T16927.1~2-1997 "High Voltage Test Techniques"
DL/T474.4-2006 "Guide for Insulation Test Implementation on Site - AC Withstand Voltage Test"
DL/T1015 "Guide for the Use of Voltage Measurement Systems for On-site DC and AC Withstand Voltage Tests"
GB/T311.1-1997 "Insulation Coordination and Insulation of High Voltage Power Transmission and Transformation Equipment"
GB191-2000 "Pictorial Markings for Packaging and Storage"
JB/T9641-1999 "Test Transformers"
IEC358(1990) "Coupling Capacitors and Capacitor Dividers"
GB4793-1984 "Safety Requirements for Electronic Measuring Instruments"
GB/T3859.2-1993 "Application Guide for Semiconductor Converters"
GB/T2423.8-1995 "Basic Environmental Testing Procedures for Electrical and Electronic Products"
DL/T849.6-2004 "General Technical Specifications for Special Test Instruments for Power Equipment Part 6: High Voltage Frequency Tuning Test Devices"
Note:

1.The appearance of the product shall be subject to the actual product,Technical parameters with model if there are any changes,without notice.In case of misappropriation or copying, legal liability will be investigated.

2. For more information about Wuhan UHV, please enter product center . Service email:info@hvtest.cc

Series resonance device Series resonance device Series resonance device Series resonance device Series resonance device Series resonance device Series resonance device Series resonance device Series resonance device

Product Picture

Product attachment drawing

Product details

Product Certificate

Enterprise products in strict accordance with international and national standards and rules of industry production, through the national, provincial and municipal electric power research institute and electric power authorities detection, measuring center, fully passed the ISO9001 international quality management system certification, the licence for manufacturing measuring instruments of the People's Republic of China, GB/T19001-2016 quality management system requirements, GB/T24001-2016 environmental management system requirements, GB/T45001-2020 occupational health and safety management system requirements.

Recommended Products