HuaTianLogo

Power detection technology / Power detection

Detection Technology

Failure phenomenon of loop resistance tester

time:2020/9/23   source:华天电力  reading:758 time

The troubleshooting method is as follows:


Trouble phenomenon:


1. No response after booting, no display on LCD


Troubleshooting:


1) Check for AC power supply;


2) Check the power cable;


3) Check whether the fuse in the fuse base is blown.


2. The resistance value is too large during the test or displayed as over-range


Troubleshooting:


1) Check whether the measured resistance value is too large;


2) Check whether the voltage input line is connected to the inside of the current output line;


3) Check whether the polarity of the test line is reversed;


4) Check whether the voltage output line is connected well, and whether the joint of the DUT is oxidized.


Micro Ohmmeter.png


3. No response from twisting the mouse


Troubleshooting:


1) Block the power and restart from the beginning;


2) Press the reset button to reset the instrument.


4. Communication is unsuccessful


Troubleshooting:


1) Check whether the data cable is connected well;


2) Check whether the instrument is online;


3) Install from scratch after uninstalling the driver;


4) Press the reset button to reset the instrument.

Copyright description: all articles, pictures, video and other materials on this site belong to wuhan huatian power automation co., LTD. For use, please contact us; Permission to reprint articles, pictures, video and other materials please quote "from: huatian power".

Discharge rod of DC high voltage generator  | 2020/9/23 | reading791time How to troubleshoot dc resistance tester?  | 2020/9/22 | reading775time return