HuaTianLogo
HEY-H HRHEA

HEY-H CT/PT Calibrator

Intelligent instrument calibrator for PT CT error and impedance admittance test

stake: About product purchase、Technical maintenance and other services,Send welcome email:

product brief introduction Product Introduction

Intelligent instrument calibrator for PT CT error and impedance admittance test.It meets the requirements of jjg313-94 current transformer verification regulation and jjg314-94 voltage transformer verification regulation.

Product nickname:transformer calibrator、Transformer current calibration instrument、Automatic transformer calibrator、Automatic current transformer calibrator、Automatic voltage transformer tester、HYHGX、Current transformer field calibrator、Voltage transformer field calibrator

Product Parameter Product Parameters

technical parameters

Equipment operating environment temperature:5℃~40℃ relative humidity:<80%(25℃时)
altitude:<2500m
mains frequency:50Hz±0.5Hz mains input:220V±5V
range of measurement cophase component(%):0.0001~200.0 distinguishability:0.0001
orthogonal component(part):0.001~700.0 distinguishability:0.001
impedance(Ω):0.0001~20.0 distinguishability:0.0001
admittance(ms):0.0001~20.0 distinguishability:0.0001
intrinsic error cophase component ΔX=±(X×2%+Y×2%)±Dx(Level 1 is optional)
orthogonal component ΔY=±(X×2%+Y×2%)±Dy(Level 1 is optional)
"X"、"Y"——Display value of instrument
"Dx,Dy"——Display value of instrument
Dx=2,Dy=5
dial indicator PETS2(Level 1 is optional)
working range electricity (1%~149%)In (In =5A)
(5%~149%)In (In =1A)
voltage (5%~149%)Un (Un =100V,150V,100V/)
(5%~149%)Un (Un =100V/3)
workload electricity TO to TX<0.12Ω cosΦ=1
voltage a to x<0.25VA (100V)
Polarity error indication When the operating current (voltage) reaches more than 5% of the rated current (voltage) and the error exceeds 180%, there should be polarity indication.
Note: if it is more than 10% of the rated operating current (voltage), there is still no proper polarity indication, indicating a fault. Please do not increase the current (voltage) to avoid burning out the instrument.
Variable ratio error indication When the operating current (voltage) reaches more than 5% of the rated current (voltage) and the error exceeds 30% but is less than 180%, the error indication of variable ratio should be given.
Insulation and voltage test and

instructions

terminalTX()Terminal is same
The power socket can withstand the housing1.5kV,1minwithstand voltage
stake:

1.The appearance of the product shall be subject to the actual product,If there are any changes in technical parameters and models,without prior notice.If there is theft or copying,Legal responsibility will be pursued.

2.For more information aboutWuhan UHV, please enter product center . Service email:info@hvtest.cc

product features Product Characteristics

Product Picture

Product attachment drawing

product detail drawing

Product Certificate

Enterprise products in strict accordance with international and national standards and rules of industry production, through the national, provincial and municipal electric power research institute and electric power authorities detection, measuring center, fully passed the ISO9001 international quality management system certification, the licence for manufacturing measuring instruments of the People's Republic of China, GB/T19001-2016 quality management system requirements, GB/T24001-2016 environmental management system requirements, GB/T45001-2020 occupational health and safety management system requirements.

Recommended Products