The high voltage dielectric loss test device is used for field anti-interference dielectric loss measurement, or precision dielectric loss measurement in the laboratory. The instrument is integrated with dielectric loss bridge, variable frequency power supply, test transformer and standard capacitor. Using frequency conversion anti-interference and Fourier transform digital filter technology, automatic intelligent measurement, strong interference measurement data is very stable. The measurement results are displayed on a large LCD screen and can be printed out by a microprinter.

product names:Dielectric loss tester, anti-interference dielectric loss tester, automatic dielectric loss tester, dissimilar frequency dielectric loss tester, dissimilar frequency dielectric loss tester, anti-interference dielectric loss tester, automatic dielectric loss tester

Product Parameters

Technical parameters

accuracy Cx ± (Reading ×1%+1pF)
tgδ ± (Reading x 1%+0.00040)
Anti-interference index Frequency conversion anti-interference, the above accuracy can still be achieved under 200% interference
Capacitance range Internal high pressure 3pF~60000pF/10kV 60pF~1μF/0.5kV
External high pressure application 3pF~1.5μF/10kV 60pF~30μF/0.5kV
Resolution Up to 0.001pF, 4 significant digits
tgδ delta range Unlimited, resolution 0.001%, capacitance, inductance, resistance three kinds of test automatic recognition
Test current range 10μA~5A
Internal high pressure Set voltage range 0.5~10kV
Maximum output current 200mA
Elevating pressure system Continuous smooth regulation
Voltage accuracy ±(1.5% x reading +10V)
Voltage resolution 1V
Test frequency 45~65Hz integer frequency, 49/51Hz, 45/55Hz automatic double frequency conversion
Frequency accuracy:±0.01Hz
External high pressure application Maximum test current during normal wiring5A/40~70Hz
Maximum test current during reverse wiring 10kV/5A/40~70Hz
CVT self-excited low voltage output Output voltage 3 ~ 50V, output current 3 ~ 30A
Measuring time About 30s, depending on the measurement method
输入电源 Input power supply
Computer interface Standard RS232 interface
printer Comes with micro thermal printer
Ambient temperature -10℃~50℃
Relative humidity <90%, no condensation
Selection of main technical indicators
Capacitance rangepF 3~60k
Maximum output currentmA 200/10kV
Overall dimensions Length x width x height cm 34x26x27cm3
weight kg 22kg
High voltage dielectric loss support
CVT self-excitation measurement No external equipment is requiredC1/C2High voltage cable can be milled at the same time
Loop discharge warning There are
printer thermosensitive
Computer interface and storage RS232 stores 100 groups
Note:

1.The appearance of the product shall be subject to the actual product,Technical parameters with model if there are any changes,without notice.In case of misappropriation or copying, legal liability will be investigated.

2. For more information about Wuhan UHV, please enter product center . Service email:info@hvtest.cc

Product Characteristics

Product Picture

Product attachment drawing

Product details

Product Certificate

Enterprise products in strict accordance with international and national standards and rules of industry production, through the national, provincial and municipal electric power research institute and electric power authorities detection, measuring center, fully passed the ISO9001 international quality management system certification, the licence for manufacturing measuring instruments of the People's Republic of China, GB/T19001-2016 quality management system requirements, GB/T24001-2016 environmental management system requirements, GB/T45001-2020 occupational health and safety management system requirements.